Features
~ 10,000 psig working pressure
~ Leakage rate on Helium is less than 1 x 10 SCCS
~ Operates with 24 +/- 4 VDC

Application
~ This device is used to shutoff the helium supply to the pneumatic control system of a rocket in the event a hold is required. This valve will hold the 10,000 psig of helium with less leakage than one bubble in 30 days.
These proprietary products illustrate TechSystems' structured and disciplined approach to product development.

Proprietary Product Gallery

Return to Products

Innovative Solutions for the Aerospace & Industrial Fluid Control Industries

10,000 psig Helium Three-Way Valve

Hydraulic Capture Tank

Features
~ Capacity of 600 in
~ Weight is less than 6.5 lbs empty
~ Emergency rupture disk designed to vent excess fluid

Application
~ This device is used to collect hydraulic fluid from a payload delivery rocket. During normal operation, the tank does not vent fluid, however, the rupture disk allows for excess fluid to be dumped overboard.